Determinação voltamétrica de estriol em formulação farmacêutica e urina utilizando um eletrodo de carbono vítreo modificado com um filme de poli(metionina) e cobalto
dc.contributor.advisor | Malagutti, Andréa Renata | |
dc.contributor.advisorco | Mourão, Henrique Aparecido de Jesus Loures | |
dc.contributor.author | Gomes, Eliziana Santana | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.contributor.referee | Malagutti, Andréa Renata | |
dc.contributor.referee | Ferreira, Lucas Franco | |
dc.contributor.referee | Lemos, Leandro Rodrigues de | |
dc.date.accessioned | 2018-07-18T12:49:10Z | |
dc.date.available | 2018-07-18T12:49:10Z | |
dc.date.issued | 2017 | |
dc.date.submitted | 2017-07-28 | |
dc.description.abstract | O estriol (C18H24O3, denominado E3) é o principal esteroide estrogênico produzido na gravidez. O uso do estriol é comum para o tratamento da menopausa como alternativa ao 17β- estradiol, estrona ou a uma combinação destes dois fármacos. O principal objetivo deste trabalho foi estudar o perfil voltamétrico do estriol utilizando a voltametria cíclica e desenvolver uma metodologia para a sua determinação em comprimidos e urina utilizando a voltametria de pulso diferencial (DPV) e o eletrodo de carbono vítreo modificado com um filme de polimetionina e cobalto. Os resultados mostraram que em solução de tampão fosfato a 0,1 mol L-1 (pH 7,0) o E3 oxidou irreversivelmente no potencial de +0,58V, apresentando uma boa definição do pico. A curva analítica para o E3 foi linear no intervalo de concentração de 0,60 μmol L-1 – 4,76 μmol L-1 (R2 = 0,996) e 5,66 μmol L-1 – 9,90 μmol L-1 (R2 = 0,994), com limites de detecção e de quantificação iguais a 3,40x10-8 mol L-1 e 1,13 x 10-7 mol L-1, respectivamente. A precisão foi avaliada através de análises voltamétricas do estriol realizadas em um mesmo dia e em dias diferentes e apresentaram desvios padrões relativos (RSD) inferiores a 5,0%, mostrando que o método desenvolvido é preciso. Os estudos sobre interferentes mostraram que as substâncias presentes nas amostras de comprimido (lactose, estearato de magnésio e amido) ou urina (ácido úrico, ácido ascórbico e ácido cítrico) não interferiram de maneira significativa na determinação do E3. Além disso, o método desenvolvido foi comparado estatisticamente com um método citado na farmacopéia através do teste-t e do teste-F. Os resultados mostraram que os valores de t e F calculados foram menores do que os valores de t e F críticos, indicando que não houve diferença estatística significativa entre os métodos. A exatidão do método foi avaliada também por estudos de adição e recuperação. As recuperações do E3 variaram de 97,7 – 100,9% para a formulação farmacêutica e 99,0 – 100,9% para a urina, indicando que não houve efeitos de interferência de matriz significativos e que o método apresenta boa exatidão. Desta forma, a validação da metodologia desenvolvida demonstrou que o método proposto pode ser aplicado com sucesso na determinação do E3 em medicamentos e urina humana. | pt_BR |
dc.description.abstracts | The estriol (C18H24O3, named as E3) is the main estrogenic steroid produced during pregnancy. The E3 is used to treatment of menopause as an alternative for 17β-estradiol, estrone or a combination of both. The main goal of this work was to study the voltammetric profile of E3 using cyclic voltammetry in order to develop a methodology for its determination in tablets and urine using differential pulse voltammetry (DPV) and the glass carbon electrode modified with a film of polymethionine and cobalt. The results showed that the E3 was oxidized at + 0.58V in a 0.1 molL-1 phosphate buffer solution (pH 7.0), giving a good peak definition. The analytical curve for E3 was linear in the concentration range of 0.60 μmolL-1 – 4.76 μmolL-1 (R2 = 0.996) and 5.66 μmolL-1 – 9.90 μmolL- 1 (R2 = 0.994 with lmits of detection and quantification of 3.40x10-8 molL-1 and 1.13x10-7 molL-1, respectively. The precision was evaluated by recording voltammograms of E3 on the same or different day. The relative standard deviations were lower than 5.0% for each test, indicating that the developed method has good precision. The interfering study showed that the tested substances do not interfered significantly in the determination of E3, as for both tablets (lactose, magnesium stearate and starch) or urine test (uric acid, ascorbic acid and citric acid). Furthermore, the developed method was compared to the suggested method from American Pharmacopoeia using the t-test and the F-test. The results showed that the calculated values of t and F were lower than their critical values, indicating no significant statistical difference between the methods. The accuracy of the method was also evaluated by studies of addition and recovery. The recovery of E3 ranged from 97.7 – 100.9% for the pharmaceutical formulation and 99.0 – 100.9% for the urine, indicating no significant effects of matrix interference and that the developed method presented accuracy. Thus, the validation of the developed methodology demonstrated that the proposed method can be applied successfully to the determination of E3 in drugs and human urine. | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | pt_BR |
dc.description.thesis | Dissertação (Mestrado) – Programa de Pós-graduação em Ciências Farmacêuticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2017. | pt_BR |
dc.identifier.citation | GOMES, Eliziana Santana. Determinação voltamétrica de estriol em formulação farmacêutica e urina utilizando um eletrodo de carbono vítreo modificado com um filme de poli(metionina) e cobalto. 2017. 101 p. Dissertação (Mestrado) – Programa de Pós-graduação em Ciências Farmacêuticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2017. | pt_BR |
dc.identifier.uri | https://acervo.ufvjm.edu.br/items/0a5e176a-34b5-4af5-8891-451c33f30440 | |
dc.language.iso | por | |
dc.publisher | UFVJM | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.license | A concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data. | pt_BR |
dc.subject.keyword | Estriol | pt_BR |
dc.subject.keyword | Eletroanálise | pt_BR |
dc.subject.keyword | Voltametria de pulso diferencial | pt_BR |
dc.subject.keyword | Eletrodo de carbono vítreo modificado com polimetionina e cobalto | pt_BR |
dc.subject.keyword | Electroanalysis | pt_BR |
dc.subject.keyword | Differential pulse voltammetry | en |
dc.subject.keyword | Polymethionine and cobalt modified glassy carbon electrode | en |
dc.title | Determinação voltamétrica de estriol em formulação farmacêutica e urina utilizando um eletrodo de carbono vítreo modificado com um filme de poli(metionina) e cobalto | pt_BR |