Desenvolvimento e validação de metodologias eletroanalíticas para determinação de fármacos antituberculose
dc.contributor.advisor | Malagutti, Andréa Renata | |
dc.contributor.author | Ferraz, Bruno Regis Lyrio | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.contributor.referee | Malagutti, Andréa Renata | |
dc.contributor.referee | Ferreira, Lucas Franco | |
dc.contributor.referee | Santos, Wallans Torres Pio dos | |
dc.date.accessioned | 2016-07-22T15:28:18Z | |
dc.date.available | 2016-07-22T15:28:18Z | |
dc.date.issued | 2016 | |
dc.date.submitted | 2016-03-11 | |
dc.description.abstract | RESUMO Etionamida e pirazinamida são antibióticos úteis no tratamento da tuberculose multirresistente. O presente trabalho descreve o desenvolvimento e validação de metodologias eletroanalíticas para determinação de etionamida e pirazinamida em formulações farmacêuticas e em urina humana empregando um eletrodo de diamante dopado com boro e um eletrodo de carbono vítreo modificado comum filme de poli glicina. Durante o desenvolvimento de ambas as metodologias, a voltametria cíclica foi empregada para verificar a influência do pH, da velocidade de varredura e do eletrólito suporte no comportamento eletroquímico de ambos os analitos, bem como foram calculados os números de prótons e elétrons envolvidos em cada uma das reações eletroquímicas. A voltametria de onda quadrada com os parâmetros otimizados foi utilizada para construir curvas analíticas para a ETO e PZA. Para a ETO foi obtido um intervalo linear de 1,0 a 80,0 μmol L1, com LOD e LOQ iguais a 0,294 e 0,980 μmol L1, respectivamente. Para a PZA foi obtido um intervalo linear de 0,47 a 6,16 μmol L1, com LOD e LOQ iguais a 0,035 e 0,12 μmol L1, respectivamente. A precisão foi avaliada pelo registro de voltamogramas no mesmo dia e em dias diferentes, obtendo-se desvios padrões relativos, inferiores a 5,0% em ambos os métodos. Os resultados dos estudos de interferentes mostraram que nenhuma das substâncias testadas interferiu de maneira significativa na determinação de ambos os fármacos. Os métodos desenvolvidos foram comparados estatisticamente com os protocolos oficiais da farmacopeia através do teste-t e do teste-F, e os resultados mostraram que os valores de t e F calculados foram menores do que os valores de t e F críticos, indicando que não houve diferença estatística entre as médias. A exatidão de ambos os métodos foi avaliada também por estudos de adição e recuperação, obtendo-se como resultados percentuais de recuperação próximos a 100% para ambos os métodos. A validação das metodologias desenvolvidas foi realizada pela avaliação dos parâmetros analíticos como sensibilidade, seletividade, limite de detecção, limite de quantificação, faixa linear, exatidão e precisão e os resultados obtidos foram satisfatórios. Portanto, os métodos desenvolvidos podem ser aplicados com sucesso na determinação dos fármacos ETO e PZA em medicamentos e urina humana. | pt_BR |
dc.description.abstracts | ABSTRACT Ethionamide and pyrazinamide antibiotics are useful in the treatment of multidrugresistant tuberculosis. This work describes the development and validation of electroanalytical methodologies for determination of ethionamide and pyrazinamide in pharmaceutical formulation and human urine using boron-doped diamond electrode and poly glycine modified glassy carbon electrode, respectively. During the development of both methodologies, cyclic voltammetry was used to investigate the influence of pH, scan rate and the supporting electrolyte on the electrochemical behavior of both analytes, as well as the numbers of protons and electrons involved in each of the electrochemical reactions were calculated. Square wave voltammetry with optimized parameters were used to construct standard curves for ETO and PZA. For ETO a linear range from 1.0 to 80.0 μmol L1 was obtained with LOD and LOQ equal to 0.294 and 0.980 μmol L1, respectively. For PZA a linear range from 0.47 to 6.16 μmol L1was obtained with LOD and LOQ equal to 0.035 and 0.12 μmol L1, respectively. The precision was evaluated by voltammograms record on the same day and on different days, obtaining relative standard deviation less than 5.0% in both methods. The results of interfering studies showed that none of the tested substance interferes significantly in the determination of both drugs. The developed methods were statistically compared with the pharmacopoeia official protocols through the t-test and F-test, and the results showed that the calculated t and F values were lower than the critical t and F values indicating that there was no statistical difference between the averages. The accuracy of both methods was also evaluated by addition and recovery studies, obtaining results as percentage recovery close to 100% for both methods. The validation of the developed methodologies was carried out by the evaluation of analytical parameters such as sensitivity, selectivity, detection limit, quantification limit, linear range, accuracy and precision and the obtained results were satisfactory. Therefore, the developed methods can be applied successfully in the determination of ETO and PZA drugs in pharmaceuticals and human urine. | pt_BR |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | pt_BR |
dc.description.sponsorship | Fundação de Amparo a Pesquisa do Estado de Minas Gerais (FAPEMIG) | pt_BR |
dc.description.thesis | Dissertação (Mestrado) – Programa de Pós-graduação em Ciências Farmacêuticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2016. | pt_BR |
dc.identifier.citation | FERRAZ, Bruno Regis Lyrio. Desenvolvimento e validação de metodologias eletroanalíticas para determinação de fármacos antituberculose. 2016. 127 p. Dissertação (Mestrado) – Programa de Pós-graduação em Ciências Farmacêuticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2016. | pt_BR |
dc.identifier.uri | https://acervo.ufvjm.edu.br/items/c92c9997-5fb9-4564-884d-dd5450707387 | |
dc.language.iso | por | |
dc.publisher | UFVJM | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.license | A concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data. | pt_BR |
dc.subject.keyword | Etionamida | pt_BR |
dc.subject.keyword | Pirazinamida | pt_BR |
dc.subject.keyword | Voltametria de onda quadrada | pt_BR |
dc.subject.keyword | Eletrodo de diamante dopado com boro | pt_BR |
dc.subject.keyword | Eletrodo de carbono vítreo modificado com poliglicina | pt_BR |
dc.subject.keyword | Métodos analíticos | pt_BR |
dc.subject.keyword | Ethionamide | pt_BR |
dc.subject.keyword | Pyrazinamide | pt_BR |
dc.subject.keyword | Square wave voltammetry | pt_BR |
dc.subject.keyword | Boron-doped diamond electrode | pt_BR |
dc.subject.keyword | Poly(glycine) glassy carbon modified electrode | pt_BR |
dc.subject.keyword | Analytical methods | pt_BR |
dc.title | Desenvolvimento e validação de metodologias eletroanalíticas para determinação de fármacos antituberculose | pt_BR |