Eletrossíntese e caracterização de filmes poliméricos aplicados ao desenvolvimento de um imunossensor para diagnóstico de Dengue
dc.contributor.advisor | Ferreira, Lucas Franco | |
dc.contributor.advisorco | Thomasini, Ronaldo Luis | |
dc.contributor.author | Santos, Cátia da Cruz | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.contributor.referee | Ferreira, Lucas Franco | |
dc.contributor.referee | Verly, Rodrigo Moreira | |
dc.contributor.referee | Franco, Diego Leoni | |
dc.contributor.referee | Castro, Cláudio Márcio de | |
dc.contributor.referee | Malagutti, Andrea Renata | |
dc.date.accessioned | 2019-12-13T21:44:55Z | |
dc.date.available | 2019-12-13T21:44:55Z | |
dc.date.issued | 2019 | |
dc.date.submitted | 2019-08-02 | |
dc.description.abstract | A infecção pelo vírus da Dengue constitui-se em uma das doenças mais negligenciadas e de maior importância para a saúde pública no mundo. É uma doença de amplo espectro clínico, incluindo desde formas brandas até quadros graves, causada por diferentes sorotipos do vírus. Não existe tratamento específico para a Dengue. No entanto, a detecção precoce e o acesso a cuidados médicos adequados reduzem as taxas de mortalidade para abaixo de 1%. Novos métodos de diagnóstico da doença têm sido estudados através da imobilização da proteína não-estrutural 1 (NS1) do vírus dengue, por esta ser um marcador utilizado durante a fase aguda da doença. Para isso, imunossensores utilizando a detecção eletroquímica têm sido explorados em várias análises, uma vez que são específicos, simples, portáteis e geralmente descartáveis e podem realizar a detecção in situ ou automatizada. Neste trabalho, realizou-se a síntese eletroquímica de filmes poliméricos derivados do ácido 4-aminobenzóico (4-ABA), 4-aminobenzamida (4-ABZ), ácido 4-hidroxibenzóico (4-HBA) e 4-hidroxibenzamida (4-HBZ) na superfície de eletrodos de grafite através da voltametria cíclica (VC). Posteriormente, foi proposto um mecanismo de eletropolimerização para os polímeros obtidos. As propriedades eletroquímicas, morfológicas e estruturais dos filmes poliméricos formados e suas aplicações na imobilização de biomoléculas foram investigadas. Desta forma, verificou-se que os eletrodos modificados com poli(4-ABA) e poli(4-HBA) foram mais eficazes na imobilização da proteína recombinante não estrutural 1 (rNS1) e de anticorpos anti-NS1. Na segunda parte deste trabalho, um novo imunossensor eletroquímico baseado em anticorpos específicos anti-NS1 acoplados a eletrodos impressos de grafite modificados com poli(4-ABA) foi desenvolvido com sucesso para o diagnóstico do vírus da Dengue. A análise de validação foi realizada com amostras de soro humano, onde após os testes sorológicos (ELISA), diferentes soros foram testados pelo teste rápido da Bioclin, e os diagnósticos foram confirmados pelo método impedimétrico utilizado neste trabalho. Os resultados obtidos foram todos positivos para a metodologia imunocromatográfica utilizada no teste rápido e para a detecção impedimétrica de anticorpos anti-NS1. A comparação entre os resultados mostra que o dispositivo fabricado pode ser aplicado satisfatoriamente para o diagnóstico preciso do vírus da Dengue, apresentando excelentes resultados, sendo assim, uma nova alternativa de detecção da Dengue. | pt_BR |
dc.description.abstracts | Dengue virus infection is one of the most neglected diseases of major importance to public health in the world. It is a disease of wide clinical spectrum, including from soft forms to severe frames, caused by different serotypes of the virus. There is no specific treatment for Dengue. However, early detection and access to adequate medical care reduce mortality rates to below 1%. New methods of diagnosis of the disease have been studied through the immobilization of dengue virus nonstructural protein 1 (NS1), as a marker used during the acute phase of the disease. For this purpose, immunoassays using electrochemical detection have been explored in several analyzes, since they are specific, simple, portable and generally disposable and can perform in situ or automated detection. In this work, the electrochemical synthesis of polymeric films derived from 4-aminobenzoic acid (4-ABA), 4-aminobenzamide (4-ABZ), 4-hydroxybenzoic acid (4-HBA) and 4-hydroxybenzamide (4-HBZ) on the surface of graphite electrodes through cyclic voltammetry (VC). Subsequently, an electropolymerization mechanism was proposed for the obtained polymers. The electrochemical, morphological and structural properties of the polymeric films formed and their applications in the immobilization of biomolecules were investigated. In this way, electrodes modified with poly(4-ABA) and poly(4-HBA) were found to be more effective immobilization of the non-structural recombinant protein 1 (rNS1) and anti-NS1 antibodies. In the second part of this work, a new electrochemical immunosensor based on specific anti-NS1 antibodies coupled to poly(4-ABA) modified graphite printed electrodes has been successfully developed for the diagnosis of Dengue virus. Validation analysis was carried with human serum samples, where after the serological tests (ELISA), different sera were tested by the Bioclin rapid test, and the diagnoses were confirmed through the impedimetric method used in this work. The results obtained were all positive for the immunochromatographic methodology used in the rapid test and for the impedimetric detection of anti-NS1 antibodies. The comparison between the results shows that the manufactured device can be applied satisfactorily for the precise diagnosis of the Dengue virus, presenting excellent results, thus being a new alternative for the detection of Dengue specific antibodies. | en |
dc.description.sponsorship | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.description.thesis | Tese (Doutorado) – Programa de Pós-Graduação Multicêntrico em Química de Minas Gerais, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2019. | pt_BR |
dc.identifier.citation | SANTOS, Cátia da Cruz. Eletrossíntese e caracterização de filmes poliméricos aplicados ao desenvolvimento de um imunossensor para diagnóstico de Dengue. 2019. 153 p. Tese (Doutorado Multicêntrico em Química) – Programa de Pós-Graduação Multicêntrico em Química de Minas Gerais, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2019. | pt_BR |
dc.identifier.uri | https://acervo.ufvjm.edu.br/items/b57bcc32-edbe-4f1b-8051-8a2a7dd5d1bd | |
dc.language.iso | por | |
dc.publisher | UFVJM | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.license | A concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data. | pt_BR |
dc.subject.keyword | Filmes poliméricos | pt_BR |
dc.subject.keyword | Eletrodos modificados | pt_BR |
dc.subject.keyword | Mecanismo de polimerização | pt_BR |
dc.subject.keyword | Antígeno rNS1 | pt_BR |
dc.subject.keyword | Imunossensores | pt_BR |
dc.subject.keyword | Polymeric films | en |
dc.subject.keyword | Modified electrodes | en |
dc.subject.keyword | Polymerization mechanism | en |
dc.subject.keyword | rNS1 antigen | en |
dc.subject.keyword | Immunosensors | en |
dc.title | Eletrossíntese e caracterização de filmes poliméricos aplicados ao desenvolvimento de um imunossensor para diagnóstico de Dengue | pt_BR |
dc.type | Tese | pt_BR |