Análise das estruturas química e física e da permeabilidade bacteriana do não tecido Spunbond-Meltblown-Spunbond (SMS) reprocessado

dc.contributor.advisorRocha Vieira, Etel
dc.contributor.advisorcoFerreira, Lucas Franco
dc.contributor.authorLima, Rayana Santos Cristianismo
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.contributor.refereeRocha Vieira, Etel
dc.contributor.refereeFerreira, Lucas Franco
dc.contributor.refereeLucas, Thabata Coaglio
dc.contributor.refereePaula, Fabiana Angélica de
dc.date.accessioned2023-07-11T21:31:55Z
dc.date.available2023-07-11T21:31:55Z
dc.date.issued2023
dc.date.submitted2023-04-05
dc.description.abstractOs profissionais de saúde estão constantemente expostos aos riscos de contágio pelo SARS-CoV-2 desde que ele foi detectado na cidade de Wuhan (China) em dezembro de 2019. A alta procura por equipamentos de proteção individual (EPI) provocou escassez no mercado mundial e elevação de custo. Como alternativa muitas instutições de saúde passaram a produzir seus próprios EPI, como máscaras cirúrgicas, a partir de um tipo de não tecido denominado Spunbond-Meltblown-Spunbond (SMS). Este estudo avaliou se o reprocessamento do SMS altera a estrutura química, física e a propriedade de filtração do material. Foram utilizadas amostras de manta de SMS nova e reprocessadas, após utilização como embalagem de caixas e instrumentais cirúrgicos. As mantas foram então submetidas a análises para avaliação das estruturas física (Microscopia Eletrônica de Varredura) e química (Reflexão Total Atenuada no Infravermelho com Transformada de Fourier). Máscaras cirúrgicas confeccionadas com mantas novas e reprocessadas foram avalidas quanto à permeabilidade bacteriana. Após o reprocessamento verificou-se, a partir da análise qualitativa do espectro ATR-FTIR, que não houve alteração da estutura química do material. Com relação à estrutura física, a análise em microscopia eletrônica de varredura sugere redução da espessura dos filamentos spunbond e contração da manta. Com relação à pemeabiliade bacteriana, a eficiência de filtração bacteriana das máscaras confeccionadas com o SMS reprocessado (98,8 ± 0,9%) não foi diferente (p=0,96, Anova one way) daquela observada para as máscaras confeccionadas com SMS novo (98,5 ± 0,5%) e também para a máscara cirúrgica comercial (98,7 ± 0,4%). Conclusão: A estrutura química do SMS não foi modificada pelo reprocessamento e a permeabilidade bacteriana da máscara cirúrgica confeccionada com SMS reprocessado não foi alterada. É proposto que a confecção de máscaras com SMS reprocessado pode ser uma alternativa promissora, sustentável e de baixo custo para a proteção de profissionais de saúde frente a emergências de saúde pública, como a pandemia da CoViD-19.pt_BR
dc.description.abstractsHealth professionals are constantly exposed to the risks of contagion by SARS-CoV-2 since it was detected in the city of Wuhan (China) in December 2019. The high demand for personal protective equipment (PPE) has caused shortages in the world market and cost increase. As an alternative, many health institutions started to produce their own PPE, such as surgical masks, from a type of nonwoven called Spunbond-Meltblown-Spunbond (SMS). This study evaluated whether SMS reprocessing alters the chemical and physical structure and the filtration property of the material. New and reprocessed SMS blanket samples were used, after being used as packaging for surgical instruments boxes and sterilization. The material was then submitted to analyzes to evaluate their physical (Scanning Electron Microscopy) and chemical (Total Attenuated Reflection in Infrared with Fourier Transform) structures. Surgical masks made with new and reprocessed SMS were evaluated for bacterial permeability. After reprocessing, no change in the chemical structure of the material was observed. About the physical structure, scanning electron microscopy analysis suggests a reduction in the thickness of the spunbond filaments and contraction of the material. Regarding bacterial permeability, the bacterial filtration efficiency of masks made with reprocessed SMS (98.8 ± 0.9%) was not different (p=0.96, Anova one way) from that observed for masks made with new SMS (98.5 ± 0.5%) and for the commercial surgical mask (98.7 ± 0.4%) used as reference. The chemical structure of SMS was not modified by reprocessing and the bacterial permeability of the surgical mask made with reprocessed SMS was not altered. It is proposed that the manufacture of masks with reprocessed SMS can be a promising, sustainable, and low-cost alternative for the protection of health professionals in the face of public health emergencies, such as the CoViD-19 pandemic.en
dc.description.thesisDissertação (Mestrado) – Programa de Pós-graduação em Ciências da Saúde, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2023.pt_BR
dc.identifier.citationLIMA, Rayana Santos Cristianismo. Análise das estruturas química e física e da permeabilidade bacteriana do não tecido Spunbond-Meltblown-Spunbond (SMS) reprocessado. 2023. 44 p. Dissertação (Mestrado em Ciências da Saúde) – Programa de Pós-Graduação em Ciências da Saúde, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2023.pt_BR
dc.identifier.urihttps://acervo.ufvjm.edu.br/items/59dd0013-9237-4b6f-b732-93e6880b8e7d
dc.language.isopor
dc.publisherUFVJMpt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.subject.keywordEquipamento de proteção individualpt_BR
dc.subject.keywordPolipropilenospt_BR
dc.subject.keywordCOVID-19pt_BR
dc.subject.keywordSARS-COV- 2pt_BR
dc.subject.keywordPersonal protective equipmenten
dc.subject.keywordPolypropylenesen
dc.subject.keywordCOVID-19en
dc.subject.keywordSARS-COV- 2en
dc.titleAnálise das estruturas química e física e da permeabilidade bacteriana do não tecido Spunbond-Meltblown-Spunbond (SMS) reprocessadopt_BR
dc.typeDissertaçãopt_BR

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
rayana_santos_cristianismo_lima.pdf
Size:
2.58 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.11 KB
Format:
Item-specific license agreed upon to submission
Description: