Comparação entre placas de reconstrução e parafusos bicorticais na fixação de fratura de mandíbulas atróficas: estudo in vitro

dc.contributor.advisorFalci, Saulo Gabriel Moreira
dc.contributor.advisorcoGalvão, Endi Lanza
dc.contributor.authorGuimarães, Marco Túllio Becheleni Ávila
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.date.accessioned2024-10-03T20:03:00Z
dc.date.issued2023
dc.date.submitted2023-07-03
dc.descriptionFalci, Saulo Gabriel Moreira; Castro, Wagner Henriques de; Campos, Felipe Eduardo Baires.pt_BR
dc.descriptionLinha de pesquisa: Lesões inflamatórias, císticas e neoplásicas da cavidade bucal.pt_BR
dc.description.abstractFraturas em mandíbulas atróficas são relativamente comuns em idosos. Atrofia e enfraquecimento tendem a ocorrer como resultado da redução da vascularização e diminuição do fluxo sanguíneo. O tratamento deste tipo de fratura é desafiador e suas opções de tratamento sofrem grande influência a depender do grau de atrofia presente. O objetivo deste estudo foi comparar dois tipos de fixação de fraturas unilaterais de corpo de mandíbulas atróficas, em grau de severidade Classe II, utilizando parafusos bicorticais e placas do sistema load bearing. Vinte mandíbulas de poliuretano foram divididas em dois grupos e tratadas da seguinte maneira: Grupo-Placa (controle), fixada por meio de uma placa de reconstrução do sistema 2.4mm e 6 parafusos monocorticais e Grupo-Parafusos (teste), fixado com 3 parafusos bicorticais instalados em posição tripoidal. Testes de compressão linear vertical foram realizados em uma máquina de ensaio universal e tiveram as forças de resistência em newtons aferidas nos deslocamentos 1, 3, 5, 7 e 10 mm. Os testes t de student e Mann-Whitney foram utilizados para verificar a diferença entre as médias e medianas, respectivamente. Os resultados mostraram diferenças significativas entre os grupos teste e controle no deslocamento de 1mm, entretanto, não foram observadas diferenças significativas nos demais deslocamentos o que indicou uma semelhança das resistências dos dois métodos de fixação estudados nestes deslocamentos. Ressalvadas as limitações metodológicas do presente estudo, podemos concluir que os parafusos bicorticais instalados em posição tripoidal apresentaram um bom desempenho no teste mecânico, sendo uma opção viável para a fixação das fraturas unilaterais de corpo em mandíbulas atróficas grau II.pt_BR
dc.description.abstractsFractures in atrophic mandibles are relatively common in the elderly. Atrophy and weakening to occur as a result of reduced vascularity and decreased blood flow. The treatment of this type of fracture is challenging and its treatment options are greatly influenced depending on the degree of atrophy present. The aim of this study was to compare two types of fixation as a treatment for unilateral body fractures of atrophic mandibles, in Class II severity, fixed with bicortical screws, compared with fixation using a load bearing system plate. Twenty polyurethane mandibles were divided into two groups and treated as follows: Plate-Group (control), fixed using a 2.4mm system reconstruction plate and 6 monocortical screws. Group-Screws (test), fixed with 3 bicortical screws installed in a tripoidal position. Vertical linear compression tests were carried out in a universal testing machine and the forces in newtons were measured at displacements 1, 3, 5, 7 and 10mm. Student's t and Mann-Whitney tests were used to verify the difference between means and medians, respectively. The results showed significant differences between the test and control groups in the 1mm displacement, however, no significant differences were observed in the other displacements, which indicated a similarity in the resistance of the two fixation methods studied, in these displacements. Except for the methodological limitations of the present study, we can conclude that bicortical screws installed in a tripoidal position performed well in the mechanical test, being a viable option for the fixation of unilateral fractures of the body in grade II atrophic mandibles.pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)pt_BR
dc.description.thesisDissertação (Mestrado) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2023.pt_BR
dc.identifier.citationGUIMARÃES, Marco Túllio Becheleni Ávila. Comparação entre placas de reconstrução e parafusos bicorticais na fixação de fratura de mandíbulas atróficas: estudo in vitro. 2023. 48 p. Dissertação (Mestrado em Odontologia) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2023.pt_BR
dc.identifier.urihttps://acervo.ufvjm.edu.br//handle/123456789/3353
dc.language.isoporpt_BR
dc.publisherUFVJMpt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.subject.keywordFratura de mandíbulapt_BR
dc.subject.keywordTratamentopt_BR
dc.subject.keywordFixação interna rígidapt_BR
dc.subject.keywordMandíbula atróficapt_BR
dc.subject.keywordCirurgia bucomaxilofacialpt_BR
dc.subject.keywordMandible fracturept_BR
dc.subject.keywordTreatmentpt_BR
dc.subject.keywordRigid internal fixationpt_BR
dc.subject.keywordAtrophic mandiblept_BR
dc.subject.keywordOral and maxillofacial surgerypt_BR
dc.titleComparação entre placas de reconstrução e parafusos bicorticais na fixação de fratura de mandíbulas atróficas: estudo in vitropt_BR
dc.typeDissertaçãopt_BR

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
marco_tullio_b_avila_guimaraes.pdf
Size:
1.25 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: