Vibração de corpo inteiro na posição estática com as mãos sobre a plataforma estimula o sistema neuromuscular potencializando a força de preensão manual
dc.contributor.advisor | Lacerda, Ana Cristina Rodrigues | |
dc.contributor.advisorco | Mendonça, Vanessa Amaral | |
dc.contributor.author | Souza, Ana Lúcia Cristino de | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.contributor.referee | Lacerda, Ana Cristina Rodrigues | |
dc.contributor.referee | Chagas, Mauro Heleno | |
dc.contributor.referee | Gomes, Wellington Fabiano | |
dc.date.accessioned | 2018-06-05T14:42:35Z | |
dc.date.available | 2018-06-05T14:42:35Z | |
dc.date.issued | 2017 | |
dc.date.submitted | 2017-09-22 | |
dc.description | Área de concentração: Aspectos físico-funcionais e reabilitação. | pt_BR |
dc.description | Na Capa da obra consta o título: "Vibração de corpo inteiro na posição estática com as mãos sobre a plataforma estimula o sistema neuromuscular potencializando a força muscular de preensão manual". | pt_BR |
dc.description.abstract | A vibração do corpo inteiro (VCI) pode ser uma modalidade ergogênica capaz de melhorar o desempenho muscular. Uma vez que a transmissibilidade deste estímulo é reduzida quando aplicado sob os pés, permanece uma lacuna no que tange a potencialização da força de preensão manual (FPM) na posição estática, com as mãos sobre a plataforma, em indivíduos saudáveis. O objetivo deste estudo foi investigar o efeito dose-resposta da exposição à vibração na posição estática, com as mãos sobre a plataforma na FPM e nos registros eletromiográficos (EMG) do músculo flexor superficial dos dedos. Vinte e oito mulheres saudáveis (idade: 27 + 8 anos, IMC: 23,2 + 4,5 kg.m-2) foram familiarizadas e submetidas de forma randomizada e aleatorizada a quatro situações experimentais: A). Sentado - mãos supinadas, apoiadas nas pernas, sem estímulo vibratório; B) Placebo – mãos posicionadas sobre a plataforma desligada e estímulo sonoro mimetizando o estímulo de vibração; C). 25Hz / 2mm e D). 45Hz / 2mm - semelhante à posição placebo com estímulo vibratório vertical sinusoidal em diferentes freqüências, com aplicação da amplitude de 2mm. O período de intervenção foi de 5 minutos em todas as situações experimentais. Antes e imediatamente após as intervenções, o desempenho muscular da mão dominante foi avaliado usando o dinamômetro de força manual (Jamar, EUA). Os registros EMG (Miotec, Brasil) ocorreram durante as situações experimentais. A razão neuronal representou a relação entre registros EMG e força de preensão. A análise estatística foi realizada por ANOVA bifatorial, com post hoc (Tukey), sendo considerado p <0,05 significativo. Como resultado, a exposição à vibração de 45Hz / 2mm resultou em um aumento de variação (pós-antes) na FPM em média de 84,6%, 93,7%, 62,6% para controle, placebo e 25Hz / 2mm, respectivamente. Este aumento foi acompanhado por uma menor relação neuronal. Os registros EMG durante o período de intervenção demonstraram que apenas a exposição ao VCI (45Hz / 2mm) aumentou os registros EMG em uma média de 94,8 % e 50,2% em relação ao controle e placebo, respectivamente. Esses achados mostram que a exposição à vibração na posição push-up modificada estática potencializou a resposta miogênica da mão de forma dose dependente. O mecanismo parece estar relacionado com a estimulação do sistema neuromuscular e a subsequente potenciação pós-ativação que defende o aprimoramento neural. | pt_BR |
dc.description.abstracts | Because the transmissibility of vibration is lower when applied under the feet, an uncertainty remains as to whether this stimulus could potentiate handgrip strength (HS) in the static modified push-up position. The aim of this study was to investigate the effect of vibration in the push-up position on HS and electromyography (EMG) of the superficial flexor muscle of the fingers. 28 healthy women (age: 27 + 8 years, BMI: 23.2 + 4.5 kg.m-2) were familiarized and submitted, to four experimental situations in a balanced, and randomized order: A). Seated supine with hands supported on the legs; B) Placebo – hands on the platform off; C). 25 Hz/2 mm/49.30 m.s-2 and, D). 45 Hz/2 mm/159.73 m.s-2 similar to the placebo position with vibration turned on. The intervention was 5-minutes in all experimental situations. Muscle performance was evaluated using the HS dynamometer (Jamar, USA). The EMG (Miotec, Brazil) was registered throughout experimental situations. The neuronal ratio represented the ratio between EMG and HS. The 45 Hz exposure resulted in an increase in variation of the HS by 84.6%, 93.7%, 62.6% relative to the control, placebo and 25 Hz, respectively. This augment was accompanied by a lower neuronal ratio. The EMG during the intervention demonstrated that only 45 Hz increased the EMG by an average of 94.8%, and 50.2% compared to the control and placebo, respectively. In conclusion, the vibration in the push-up position potentiated the HS. The mechanism seems to be related to the stimulation of the neuromuscular system and subsequent post-activation potentiation advocating neural enhancement. | en |
dc.description.thesis | Dissertação (Mestrado Profissional) – Programa de Pós-Graduação em Reabilitação e Desempenho Funcional, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2017. | pt_BR |
dc.description.thesis | Dissertação (Mestrado Profissional) – Programa de Pós-Graduação em Reabilitação e Desempenho Funcional, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2017. | pt_BR |
dc.identifier.citation | SOUZA, Ana Lúcia Cristino de. Vibração de corpo inteiro na posição estática com as mãos sobre a plataforma estimula o sistema neuromuscular potencializando a força de preensão manual. 2017. 46 p. Dissertação (Mestrado) – Programa de Pós-Graduação em Reabilitação e Desempenho Funcional, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2017. | pt_BR |
dc.identifier.uri | https://acervo.ufvjm.edu.br/items/1521875d-2756-4545-a045-413b075f2a45 | |
dc.language.iso | por | |
dc.publisher | UFVJM | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.license | A concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data. | pt_BR |
dc.subject.keyword | Vibração | pt_BR |
dc.subject.keyword | Desempenho muscular | pt_BR |
dc.subject.keyword | Força de preensão manual | pt_BR |
dc.subject.keyword | EMG | pt_BR |
dc.subject.keyword | Exposure to vibration | en |
dc.subject.keyword | Muscular performance | pt_BR |
dc.subject.keyword | Grip strength | en |
dc.subject.keyword | EMG records | en |
dc.title | Vibração de corpo inteiro na posição estática com as mãos sobre a plataforma estimula o sistema neuromuscular potencializando a força de preensão manual | pt_BR |
dc.type | Dissertação | pt_BR |