Efeitos do uso crônico de palmilhas com cunha medial em indivíduos com pronação excessiva sobre os aspectos cinéticos e cinemáticos: um estudo longitudinal

dc.contributor.advisorTrede Filho, Renato Guilherme
dc.contributor.advisorcoResende, Renan Alves
dc.contributor.authorVieira, Fernanda Muniz
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.contributor.refereeTrede Filho, Renato Guilherme
dc.contributor.refereeOliveira, Vinicius Cunha de
dc.contributor.refereeSantos, Thiago Ribeiro Teles dos
dc.date.accessioned2020-06-03T18:24:46Z
dc.date.available2020-06-03T18:24:46Z
dc.date.issued2019
dc.date.submitted2019-09-27
dc.description.abstractIntrodução: As palmilhas com cunha medial e suporte do arco longitudinal medial agem como barreira mecânica contra a eversão de calcâneo assim, limitando a pronação excessiva do pé. Devido aos acoplamentos articulares dos membros inferiores, a redução da eversão do calcâneo impede que o joelho e o quadril rode medialmente de forma livre, reduzindo o torque externo eversor de calcâneo, aumentando o torque externo adutor de joelho e reduzindo o torque externo rotador medial de joelho e quadril. Entretanto, a maior parte dos estudos avaliam os efeitos imediatos das palmilhas sobre a biomecânica da marcha, não dando respaldo científico se esses efeitos seriam mantidos com o passar do tempo. Objetivo: Avaliar os efeitos imediatos e a longo prazo do uso de palmilhas com cunha medial na cinemática e cinética dos membros inferiores durante a marcha em indivíduos com pronação excessiva dos pés. Métodos: Dezenove indivíduos com idade média de 27,3 anos, IMC de 21,6 kg/m² e pontuação de 9,87 no Foot Posture Index (FPI) foram recrutados. Os sujeitos realizaram uma caminhada usando uma palmilha intervenção com suporte de arco longitudinal medial e cunha medial de 6º de inclinação no retropé e uma palmilha controle plana. Os dados cinemáticos e cinéticos foram obtidos utilizando um sistema de captura de movimento tridimensional com 9 câmeras (Oqus 3+, Qualisys Medical AB, Gothenburg, Suécia) captando a uma frequência de 200 Hz, sincronizado com três plataformas de força FP4060-08 (Bertec, Columbus, Ohio, EUA) captando a uma frequência de 1000 Hz. Essas coletas foram realizadas em três momentos (T1: coleta imediata; T2: após 6 semanas e T3: após 12 semanas) durante o período de três meses de uso das palmilhas intervenção pelos voluntários. Resultados: Ao utilizar a palmilha intervenção em comparação com a palmilha controle, os voluntários apresentaram uma redução no pico de eversão do calcâneo (p < 0,001, pη2 = 0,72), redução do torque externo eversor de calcâneo (p < 0,001, pη2 = 0,73) e redução na amplitude de movimento no plano coronal (p < 0,001, pη2 = 0,60), tanto no momento imediato quanto a longo prazo. Na articulação do joelho, ao utilizar a palmilha intervenção houve redução no pico de rotação medial (p = 0,015, pη2 = 0,46) e no pico de torque externo de rotação medial (p = 0,001, pη2 = 0,44) durante o primeiro momento (T1) e após seis semanas (T2), deixando de ser significativo após 12 semanas de uso (T3). Houve também um aumento do pico de torque externo adutor de joelho (p < 0,001, pη2 = 0,68), com efeitos imediatos e a longo prazo (T1-T3). No quadril, os voluntários demostraram uma redução no pico de rotação medial (p = 0,002, pη2 = 0,41) e pico de torque externo rotador medial (p = 0,025, pη2 = 0,25) e um aumento do pico de abdução do quadril (p = 0,005, pη2 = 0,37) ao utilizar a palmilha intervenção, entretanto essas diferenças ocorreram somente a longo prazo (T3). Já o pico de torque externo rotador lateral do quadril (p < 0,001, pη2 = 0,61) e o pico de torque externo abdutor do quadril (p = 0,001, pη2 = 0,48) aumentaram ao usar a palmilha intervenção, com efeitos imediatos e a longo prazo (T1-T3). Conclusões: A intervenção por palmilhas com suporte do arco longitudinal medial e cunha medial em comparação a uma palmilha controle modifica a cinemática e cinética dos membros inferiores durante a marcha em adultos com pronação excessiva, reduzindo o pico de rotação medial do quadril a longo prazo e aumentando o torque externo adutor de joelho e diminuindo o pico de eversão do calcâneo, a curto e longo prazo.pt_BR
dc.description.abstractsIntroduction: Medially wedged insoles with medial longitudinal arch support act as a mechanical barrier against calcaneal eversion, limiting excessive foot pronation. Due to lower limb joint couplings, reduced calcaneal eversion prevents the free internal rotation of knee and hip, reduces calcaneal external evertor torque, increases knee external adductor torque and reduces knee and hip external medial rotator torque. However, most studies evaluate the immediate effects of the insoles on gait biomechanics, allowing no scientific support if these effects would be sustained over time. Purpose: To evaluate the immediate and long-term effects of using medially wedged insoles on lower limb kinematics and kinetics during gait in subjects with excessive foot pronation. Methods: Nineteen subjects with a mean age of 27,3 years, Body Mass Index (BMI) of 21,6 kg/m² and a Foot Posture Index mean score of 9,87 were recruited. The subjects walked wearing a 6° medially wedged insole with medial longitudinal arch support (hereafter intervention insole) and a flat control insole. Kinematic and kinetic data were obtained using a 9- camera three-dimensional motion capture system (Oqus 3+, Qualisys Medical AB, Gothenburg, Sweden) capturing at 200 Hz, synchronized with three FP4060-08 force plates (Bertec, Columbus, Ohio, USA) sampled at 1000 Hz. Data collection were performed in three moments (T1: Immediate collection; T2: After a 6 weeks intervention and T3: after 12 weeks) during the three-month intervention period. Results: The volunteers showed a reduced calcaneal eversion peak (p < 0,001, pη2 = 0,72), reduced calcaneal eversion external torque (p < 0,001, pη2 = 0,73) and a reduced coronal plane range of motion (p < 0,001, pη2 = 0,60) at the immediate and long-term period of use the intervention insole. At knee joint, the intervention insole decreased the internal rotation peak (p = 0,015, pη2 = 0,46) and decreased the internal rotation external torque peak (p = 0,001, pη2 = 0,44) during the first moment (T1) and after six weeks (T2), becoming not significant after twelve weeks of intervention. There was also an increased knee adduction external torque peak (p < 0,001, pη2 = 0,68), with immediate and long-term effects (T1- T3). The hip data showed a reduced internal rotation peak (p = 0,002, pη2 = 0,41), a reduced internal rotation external torque peak (p = 0,025, pη2 = 0,25) and an increased hip abduction peak (p = 0,005, pη2 = 0,37) wearing the intervention insoles, however these differences occurred only at the long-term period (T3). The peak of lateral rotator external torque (p < 0,001, pη2 = 0,61) and peak of abductor external torque (p = 0,001, pη2 = 0,48) increased when using the intervention insole, with immediate effects and long term (T1- T3). Conclusions: Intervention insole compared with control one effectively modify lower limb kinematics and kinetics during gait in adults with excessive pronation, decreasing the hip internal rotation peak at long term period, increasing the knee adduction external torque and reducing the calcaneal eversion peak at the short and long term period.en
dc.description.thesisDissertação (Mestrado) – Programa de Pós-Graduação em Reabilitação e Desempenho Funcional, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2019.pt_BR
dc.identifier.citationVIEIRA, Fernanda Muniz. Efeitos do uso crônico de palmilhas com cunha medial em indivíduos com pronação excessiva sobre os aspectos cinéticos e cinemáticos: um estudo longitudinal. 2019. 73 p. Dissertação (Mestrado em Reabilitação e Desempenho Funcional) – Programa de Pós-Graduação em Reabilitação e Desempenho Funcional, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2019.pt_BR
dc.identifier.urihttps://acervo.ufvjm.edu.br/items/122e607c-4a9b-4a4b-84a4-a0ab0544af21
dc.language.isopor
dc.publisherUFVJMpt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.subject.keywordPalmilhaspt_BR
dc.subject.keywordCunha medialpt_BR
dc.subject.keywordPronaçãopt_BR
dc.subject.keywordCinemáticapt_BR
dc.subject.keywordCinéticapt_BR
dc.subject.keywordMarchapt_BR
dc.subject.keywordInsolesen
dc.subject.keywordMedial wedgeen
dc.subject.keywordPronationen
dc.subject.keywordKinematicen
dc.subject.keywordKineticen
dc.subject.keywordGaiten
dc.titleEfeitos do uso crônico de palmilhas com cunha medial em indivíduos com pronação excessiva sobre os aspectos cinéticos e cinemáticos: um estudo longitudinalpt_BR
dc.typeDissertaçãopt_BR

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
fernanda_muniz_vieira.pdf
Size:
2.55 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.11 KB
Format:
Item-specific license agreed upon to submission
Description: