Desempenho clínico do Cimento de Ionômero de Vidro de alta viscosidade versus Cention® N em molares decíduos: um ensaio clínico randomizado
dc.contributor.advisor | Galo, Rodrigo | |
dc.contributor.advisorco | Silva, Thiago Fonseca | |
dc.contributor.author | Duarte, Ana Caroline Alves | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.contributor.referee | Galo, Rodrigo | |
dc.contributor.referee | Araújo, Cíntia Tereza Pimenta de | |
dc.contributor.referee | Andrade, Raquel Gonçalves Vieira de | |
dc.date.accessioned | 2020-10-05T13:50:41Z | |
dc.date.available | 2020-10-05T13:50:41Z | |
dc.date.issued | 2019 | |
dc.date.submitted | 2019-08-07 | |
dc.description | Área de concentração: Odontopediatria. | pt_BR |
dc.description.abstract | O conhecimento dos processos bioquímicos relacionados à cárie proporcionou o desenvolvimento da Odontologia de Mínima Intervenção. Sua prática vem crescendo consideravelmente e tem se tornado de grande interesse para saúde publica. É importante ressaltar que dentro dessa proposta é almejado que o material restaurador apresente características antimicrobianas e favoreça a remineralização, uma vez que a higiene bucal inadequada é um fator desafiador na prática clínica diária. Neste contexto, o objetivo desta pesquisa foi verificar o desempenho clínico do tratamento restaurador em molares decíduos com a utilização do material Cention® N (Ivoclar Vivadent) comparado ao Cimento de Ionômero de Vidro (CIV) de alta viscosidade (Riva Light Cure - SDI). Crianças com idade entre 7 e 10 anos apresentando molares decíduos com lesões oclusais foram incluídos no presente estudo. Após a remoção seletiva da cárie, os dentes foram restaurados com Cention® N e CIV de alta viscosidade. Todos os procedimentos foram realizados sob isolamento relativo adotando a abordagem do ART (Atraumatic Restorative Treatment). Após três meses, a performance clínica das restaurações foram avaliadas utilizando o critério modificado do Serviço de Saúde Pública (USPHS) e critério do ART. Além disso, o tempo despendido em cada procedimento restaurador também foi coletado. Dados socioeconômicos e demográficos das crianças e suas famílias foram coletados por meio de questionários pré-estruturados. As análises estatísticas foram realizadas através do programa SPSS versão 22.0. Foram realizadas análises descritivas da amostra, e adotou-se o teste Qui-quadrado e associação de tendência linear para avaliar a associação entre cada critério de avaliação clínica entre os diferentes materiais restauradores. A diferença entre o tempo médio gasto nos procedimentos restauradores dos diferentes materiais foi avaliada através do teste Mann-Whitney. Considerou-se valor de p <0,05 como estatisticamente significativo. Concluiu-se no presente estudo que não houve diferença estatisticamente significativa entre as restaurações classe I realizadas com CIV de alta viscosidade e Cention® N após a remoção seletiva do tecido cariado dos molares decíduos. Porém, embora não significativos, o Cention® N apresentou um melhor desempenho quando comparado ao CIV de alta viscosidade nos critérios avaliados. | pt_BR |
dc.description.abstracts | The knowledge of caries-related biochemical processes led to the development of Minimal Intervention Dentistry. Its practice has considerably grown and has become of great interest to public health. It is important to emphasize that, within this proposal, it is intended that the restorative material has antimicrobial characteristics and provides remineralization, since inadequate oral hygiene is a challenging factor in daily clinical practice. In this context, the objective of this research was to verify the clinical performance of restorative treatment in primary molars using Cention® N (Ivoclar Vivadent) compared to high viscosity Glass Ionomer Cement - GIC (RIVA Light Cure - SDI). Children aged 7 to 10 years presenting primary molars with occlusal lesions were included in the present study. After selective caries removal, the teeth were restored with Cention® N or high viscosity GIC. All procedures were performed under relative isolation using the Atraumatic Restorative Treatment (ART) approach. After 3 months, the clinical performance of the restorations was evaluated using modified Public Health Service (USPHS) and ART criteria. In addition, the time spent on each restorative procedure was also recorded. Socioeconomic and demographic data of the children and their families were collected through pre-structured questionnaires. Statistical analyzes were performed using SPSS version 22.0. Descriptive analyzes of the sample were performed, and the Chi-Square test and linear trend association were adopted to evaluate the association between each clinical evaluation criterion and the different restorative materials. The difference between the average time spent on restorative procedures both materials was evaluated using the Mann-Whitney test. Results with p values <0.05 were considered statistically significant. It was concluded in the present study that there was no statistically significant difference between Class I high-viscosity GIC and Cention® N restorations after selective caries removal in primary molars. However, although not statistically significant, Cention® N presented better clinical performances when compared to high viscosity GIC in the evaluated criteria. | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | pt_BR |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG) | pt_BR |
dc.description.thesis | Dissertação (Mestrado) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2019. | pt_BR |
dc.identifier.citation | DUARTE, Ana Caroline Alves. Desempenho clínico do Cimento de Ionômero de Vidro de alta viscosidade versus Cention® N em molares decíduos: um ensaio clínico randomizado. 2019. 65 p. Dissertação (Mestrado em Odontologia) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2019. | pt_BR |
dc.identifier.uri | https://acervo.ufvjm.edu.br/items/aabe3721-95a9-4217-aa41-4f37515f4fd3 | |
dc.language.iso | por | |
dc.publisher | UFVJM | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.license | A concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data. | pt_BR |
dc.subject.keyword | Cárie dentária | pt_BR |
dc.subject.keyword | Adaptação marginal dentária | pt_BR |
dc.subject.keyword | Dente decíduo | pt_BR |
dc.subject.keyword | Análise de sobrevida | pt_BR |
dc.subject.keyword | Dental caries | en |
dc.subject.keyword | Marginal dental adaptation | en |
dc.subject.keyword | Primary tooth | en |
dc.subject.keyword | Survival analysis | en |
dc.title | Desempenho clínico do Cimento de Ionômero de Vidro de alta viscosidade versus Cention® N em molares decíduos: um ensaio clínico randomizado | pt_BR |
dc.type | Dissertação | pt_BR |