Desenvolvimento e aplicação de um sensor voltamétrico para análise simultânea de dopamina, ácido ascórbico e ácido úrico empregando um eletrodo modificado com naftoquinona adsorvida sobre nanotubos de carbono
dc.contributor.advisor | Luz, Rita de Cássia Silva | |
dc.contributor.author | Oliveira, Ananda Xavier | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.contributor.referee | Damos, Flávio Santos | |
dc.contributor.referee | Malagutti, Andréa Renata | |
dc.contributor.referee | Teófilo, Reinaldo Francisco | |
dc.date.accessioned | 2015-02-27T18:10:13Z | |
dc.date.available | 2015-02-27T18:10:13Z | |
dc.date.issued | 2012 | |
dc.date.submitted | 2012 | |
dc.description.abstract | O presente trabalho descreve o desenvolvimento de um sensor voltamétrico altamente seletivo e sensível para dopamina (DA), ácido ascórbico (AA) e ácido úrico (AU) utilizando um eletrodo de grafite pirolítico de plano basal modificado com 1,4-naftoquinona adsorvida sobre nanotubos de carbono de paredes múltiplas (EGPPB/NTCPM/NQ). Imagens de Microscopia Eletrônica de Varredura foram utilizadas para caracterizar os materiais. Os processos de oxidação de DA, AA e AU foram investigados por Voltametria Cíclica (VC) e Voltametria de Pulso Diferencial (VPD). O eletrodo modificado apresentou excelente atividade catalítica para oxidação de DA, AA e AU, fornecendo três picos voltamétricos bem definidos em aproximadamente – 0,050, 0,145 e 0,270 V vs. Ag/AgCl, respectivamente, por VPD. Após a otimização dos parâmetros experimentais (solução 0,1 mol L-1 de tampão fosfato pH 7,5), obteve-se as curvas analíticas para DA, AA e AU, cujas faixas de linearidade foram 10,0-70,0 nmol L-1, 40,0-280,0 µmol L-1 e 2,0-14,0 µmol L-1, respectivamente. Os limites de detecção e sensibilidade foram, respectivamente, 0,126 nmol L-1 e 0,653 µA/ nmol L-1 para DA, 2,136 µmol L-1 e 0,076 µA/ µmol L-1 para AA e 0,018 µmol L-1 e 9,888 µA/ µmol L-1 para AU. O sensor foi aplicado com sucesso em amostras de urina humana e os resultados mostraram que o mesmo não sofre interferência da matriz biológica. Estudos de adição e recuperação dos analitos foram realizados para avaliar a exatidão do método e obteve-se uma porcentagem de recuperação entre 95,14% e 101,49% para DA, 96,10% e 103,47% para AA e 97,90% e 102,32% para AU. | pt_BR |
dc.description.abstracts | The present work describes the development of a highly selective and sensitive voltammetric sensor for dopamine (DA), ascorbic acid (AA) and uric acid (AU) using a basal plane pyrolytic graphite electrode modified with 1,4-naphthoquinone adsorbed on multi-walled carbon nanotubes (EGPPB/NTCPM/NQ). Images of Scanning Electron Microscopy were used to characterize the materials. Oxidation process of DA, AA and AU were investigated by Cyclic Voltammetry (VC) and Differential Pulse Voltammetry (VPD). The modified electrode showed an excellent catalytic activity towards the oxidations of DA, AA and AU, providing three well-defined voltammetric peaks at – 0.050, 0.145 e 0.270 V vs. Ag/AgCl, respectively, by VPD. After optimization of experimental parameters (0.1 mol L-1 phosphate buffer solution pH 7.5), the calibration plots were obtained for DA, AA and AU, in the range from 10.0 up to 70.0 nmol L-1, 40.0 up to 280.0 µmol L-1 and 2.0 up to 14.0 µmol L-1, respectively. The detection limit and sensitivity were, respectively, 0.126 nmol L-1 and 0.653 µA/ nmol L-1 for DA, 2.136 µmol L-1 and 0.076 µA/ µmol L-1 for AA and 0.018 µmol L-1 and 9.888 µA/ µmol L-1 for AU. The sensor developed has been successfully applied in human urine samples and the results showed that the matrix biological does not affect the response of the sensor. Studies of addition and recovery for DA, AA and AU were carried out to evaluate the error of the method and was verified a recovery percentage between 95.14% and 101.49% for DA, 96.10% and 103.47% for AA and 97.90% and 102.32% for AU. | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (Capes) | pt_BR |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do estado de Minas Gerais (FAPEMIG) | pt_BR |
dc.description.thesis | Dissertação (Mestrado) – Programa de Pós-Graduação em Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2012. | pt_BR |
dc.identifier.citation | OLIVEIRA, Ananda Xavier. Desenvolvimento e aplicação de um sensor voltamétrico para análise simultânea de dopamina, ácido ascórbico e ácido úrico empregando um eletrodo modificado com naftoquinona adsorvida sobre nanotubos de carbono. 2012. 83 p. Dissertação (Mestrado) – Programa de Pós-Graduação em Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, [2012]. | pt_BR |
dc.identifier.uri | http://acervo.ufvjm.edu.br:8080/jspui/handle/1/546 | |
dc.language.iso | por | |
dc.subject.keyword | Química | pt_BR |
dc.subject.keyword | Ciências Exatas | pt_BR |
dc.subject.keyword | Dopamina | pt_BR |
dc.subject.keyword | Ácido ascórbico | pt_BR |
dc.subject.keyword | Ácido úrico | pt_BR |
dc.subject.keyword | 1,4-naftoquinona | pt_BR |
dc.subject.keyword | Nanotubos de carbono de paredes múltiplas | pt_BR |
dc.subject.keyword | Eletrodo de grafite pirolítico de plano basal | pt_BR |
dc.title | Desenvolvimento e aplicação de um sensor voltamétrico para análise simultânea de dopamina, ácido ascórbico e ácido úrico empregando um eletrodo modificado com naftoquinona adsorvida sobre nanotubos de carbono | pt_BR |
dc.type | Dissertação | pt_BR |