Determinação de colchicina em formulações farmacêuticas e urina por amperometria de múltiplos pulsos em sistema FIA usando eletrodo de diamante dopado com boro
dc.contributor.advisor | Santos, Wallans Torres Pio dos | |
dc.contributor.author | Moreira, Débora Aparecida Rocha | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.contributor.referee | Santos, Wallans Torres Pio dos | |
dc.contributor.referee | Ferreira, Lucas Franco | |
dc.contributor.referee | Silva, Rodrigo Amorim Bezerra da | |
dc.date.accessioned | 2016-01-07T11:59:23Z | |
dc.date.available | 2016-01-07T11:59:23Z | |
dc.date.issued | 2015 | |
dc.date.submitted | 2015-07-23 | |
dc.description | Área de concentração: Química Analítica. | pt_BR |
dc.description.abstract | A colchicina (CO) é um medicamento utilizado no tratamento da artrite gotosa com ação anti-inflamatória. Este medicamento pertence a uma classe de compostos chamados de baixo índice terapêutico, cuja dose tóxica é muito próxima da dose terapêutica. Assim, a determinação de CO em formulações farmacêuticas e em fluidos biológicos é de maior importância para o controle de qualidade nos estudos farmacêuticos e farmacológicos na condução da eliminação da droga. Neste contexto, o presente trabalho apresenta métodos simples, rápidos e de baixos custos para determinação de CO em formulações farmacêuticas e urina por amperometria de múltiplos pulsos (MPA) com análise de injeção em fluxo, sistema (FIA), usando eletrodo de diamante dopado com boro (BDD). O estudo foi realizado em diferentes eletrólitos, Britton-Robinson de pH que variou de 2 a 12, solução de hidróxido de sódio e ácido sulfúrico, ambos na concentração de 0,1 mol L-1. As melhores condições para o eletrólito de suporte foi em ácido sulfúrico 0,1 mol L-1, em que a CO apresentou processos de oxidação em 1,20 e 1,41 V e uma redução de detecção em -0,9 V. MPA foi baseado na aplicação potencial dos dois impulsos de: (1) para a oxidação de CO e (2) para a redução do produto gerado, o qual foi utilizado para a determinação das amostras de fármacos. Assim, no sistema FIA-MPA foram aplicados pulsos potenciais de 1,7 V / 500 ms e -1,1V / 30 ms. Os demais parâmetros foram otimizados como: taxa de fluxo e volume da amostra em 4,5 mL min-1 e 330 μL, respectivamente. Sob estas condições, foi obtida duas faixas lineares de 0,1 à 2,0 μ mol L-1 e 20 x 10-5 a 500 x 10-4 mol L-1 com coeficiente de correlação linear de 0,992 e 0,998, respectivamente. O limite de detecção obtido foi de 2,14 x 10-8 mol L-1 para o CO. O desvio padrão relativo de injeções consecutivas de 10 respostas sobre a concentração de CO de 1,0 x 10-4 mol L-1 foi de 1,28% em -1.1 V. O sistema foi validado em comparação com o método oficial (HPLC / UV). Os resultados das recuperações obtidas por meio do método proposto para ambas as amostras foram próximo a 100%. Portanto, o método proposto por FIA-MPA utilizando eletrodo BDD pode ser aplicado com sucesso para a determinação de CO em amostras de urina e farmacêuticas, com vantagens em relação ao método oficial e outros métodos descritos na literatura. | pt_BR |
dc.description.abstracts | ABSTRACT The Colchicine (CO) is a drug used in treatment of gouty arthritis with anti-inflammatory action. This medication belongs to a class of compounds called low therapeutic index, whose toxic dose is much close to the therapeutic dose. Thus, the determination of CO in pharmaceutical formulations and in biological fluids is of the utmost importance for the quality control in pharmaceutical and pharmacological studies in conducting the elimination of the drug. In this context, the present work presents simple, fast and low-cost methods for determination of CO in pharmaceutical formulations and urine by multiple-pulse amperometric (MPA) with flow-injection analysis (FIA) system using boron-doped diamond (BDD) electrode. Study was carried out in different electrolytes, Britton-Robinson buffer pH ranging from 2 to 12, sodium hydroxide solution and sulfuric acid, both at a concentration of 0.1 mol L-1. The best conditions for the support electrolyte was sulfuric acid 0.1 mol L-1, where the CO showed oxidation processes at 1.20 and 1.41 V and one of reduction at -0.9 V. MPA detection was based on the potential application of two pulses: (1) for oxidation of CO and (2) for reduction in the generated product, which was used for the determination of the drug in the samples. Thus, in the FIA-MPA system were applied potential pulses of 1.7 V / 500ms and -1.1V / 30ms. The other parameters were optimized as: flow rate and sample volume in 4.5 mL min-1 and 330 μL, respectively. Under these conditions, it was achieved two linear ranges of 0.1 to 2.0 μmol L-1 and of 20 to 500 μmol L-1 with great linear correlation coefficient for both ranges 0.992 and 0.998 respectively. The limit of detection obtained was of 2.14 x 10-8 mol L-1 for CO. Relative standard deviation of injections of 10 consecutive responses on CO concentration of 1.0 x 10-4 mol L-1 was 1.28% at -1.1 V. The system was validated in comparison with the official method (HPLC / UV). The results of the recoveries obtained through the proposed method for both samples are around 100%. Therefore, the method proposed by FIA-MPA using BDD electrode can be successfully applied for the determination of CO in pharmaceutical and urine samples, with advantages in relationship official method and others methods described in the literature. | en |
dc.description.thesis | Dissertação (Mestrado) – Programa de Pós-Graduação em Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2015. | pt_BR |
dc.identifier.citation | MOREIRA, Débora Aparecida Rocha. Determinação de colchicina em formulações farmacêuticas e urina por amperometria de múltiplos pulsos em sistema FIA usando eletrodo de diamante dopado com boro. 2015. 63 p. Dissertação (Mestrado) – Programa de Pós-Graduação em Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2015. | pt_BR |
dc.identifier.uri | https://acervo.ufvjm.edu.br/items/a213a772-c563-44f7-8e20-1e23031b4f00 | |
dc.language.iso | por | |
dc.publisher | UFVJM | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.license | A concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data. | pt_BR |
dc.subject.keyword | Colchicina | pt_BR |
dc.subject.keyword | Amperometria de múltiplos pulsos | pt_BR |
dc.subject.keyword | Análise por Injeção em Fluxo (FIA) | pt_BR |
dc.subject.keyword | Diamante dopado com boro | pt_BR |
dc.subject.keyword | Análises farmacêuticas | pt_BR |
dc.title | Determinação de colchicina em formulações farmacêuticas e urina por amperometria de múltiplos pulsos em sistema FIA usando eletrodo de diamante dopado com boro | pt_BR |
dc.title.alternative | determination of colchicine in pharmaceutical formulations and urine by multiple-pulse amperometric in FIA system using boron-doped diamond electrode | en |
dc.type | Dissertação | pt_BR |