Estudo clínico da acurácia da localização eletrônica na constrição apical e respectiva concordância radiográfica

dc.contributor.advisorSoares, Janir Alves
dc.contributor.authorFernandes, Vanessa Cruz Silva
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.contributor.refereeSoares, Janir Alves
dc.contributor.refereeNunes, Eduardo
dc.contributor.refereeCésar, Carlos Augusto Santos
dc.date.accessioned2015-11-19T17:53:54Z
dc.date.available2015-11-19T17:53:54Z
dc.date.issued2014
dc.date.submitted2014-08-29
dc.description.abstractIntrodução: Terapeuticamente a constrição apical é referência do comprimento de trabalho (CT) dos canais radiculares (CR). Objetivo: Avaliar clinicamente fatores associados à acurácia do localizador apical eletrônico (LAE) Apex Finder A.F.A. 7005 na determinação da constrição apical. Metodologia: Para cada CR, uma lima tipo Kerr selecionada e acoplada ao LAE foi inserida intracanalmente até obter estável marcação, 1 mm no painel digital (LCD). Na radiografia periapical correspondente à distância da ponta da lima ao vértice dentário foi categorizada como precisa (0.5 a 1.5 mm), aceitável (0 a 2 mm) ou imprecisa (demais medidas). A concordância foi analisada em função do grupo de dentes, estado pulpar e periapical, diâmetro do CR e diâmetro da lima exploratória. A influência das variáveis independentes foi analisada pelos testes Mann-Whitney, Kruskal-Wallis e Correlação de Sperman (p<0,05). Resultados: Os dentes anteriores (n=21), pré-molares (n=20) e molares (n=33) proveram 147 CR, dos quais 43.5% eram atrésicos. Em 102 (69,4%) a polpa estava necrótica, dentre os quais 70 (47,6%) apresentavam radiolucidez periapical. Obteve-se elevada concordância entre a medida eletrônica e radiográfica. Verificou-se que 70,7% e 94,5% das medidas foram do tipo precisas ou aceitáveis, respectivamente. A acurácia das medidas correlacionou-se positivamente com as limas exploratórias e negativamente com o diâmetro do CR. Nenhuma variável independente influenciou a acurácia do LAE (p>0.05). Conclusão: O Apex Finder proveu medidas de CT com elevada aceitabilidade clínica na região da constrição apical, independentemente do estado pulpar, grupo dentes, estado periapical ou diâmetro dos canais radiculares.pt_BR
dc.description.abstractsABSTRACT of root canals (RC). Objective: To evaluate clinically associated factors with the accuracy of the electronic apex locator (EAL) Apex Finder A.F.A. 7005 in determination of apical constriction. Methodology: For each RC, one selected file type Kerr and coupled at EAL was inserted intracanal until stablished marking, 1 mm on the liquid-crystal display (LCD). The periapical radiograph correspondent the distance of the file tip to the tooth apex was classified as specify (0.5 to 1.5 mm), acceptable (0 to 2 mm) or imprecise (other steps). The agreement was analyzed according to the group of teeth, pulpal and periapical status, RC diameter and exploratory file diameter. The influence of independent variables was analyzed by Mann-Whitney, Kruskal-Wallis and Spearman correlation (p <0.05) tests. Results: The anterior teeth (n=21), premolars (n=20) and molars (n=33) provided RC 147, of which 43.5% were atresic. In 102 (69.4%) the pulp was necrotic, among which 70 (47.6%) had periapical radiolucency. High agreement between the electronic and radiographic measurement was obtained. It was found that 70.7% and 94.5% of the measurements are accurate and acceptable type, respectively. The accuracy of measurements correlated positively with exploratory files and negatively with the diameter of RC. No independent variable influenced the accuracy of LAE (p> 0.05). Conclusion: The Apex Finder provided measures of WL with high clinical acceptability in apical constriction, regardless of status pulp, tooth group, periapical status or diameter of the root canals.en
dc.description.thesisDissertação (Mestrado) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2014.pt_BR
dc.identifier.citationFERNANDES, Vanessa Cruz Silva. Estudo clínico da acurácia da localização eletrônica na constrição apical e respectiva concordância radiográfica. 2014. 58 p. Dissertação (Mestrado) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2014.pt_BR
dc.identifier.urihttp://acervo.ufvjm.edu.br:8080/jspui/handle/1/752
dc.language.isopor
dc.publisherUFVJMpt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.subject.keywordComprimento de trabalhopt_BR
dc.subject.keywordConstrição apicalpt_BR
dc.subject.keywordLimite apicalpt_BR
dc.subject.keywordLocalizador apical eletrônicopt_BR
dc.subject.keywordOdontometriapt_BR
dc.titleEstudo clínico da acurácia da localização eletrônica na constrição apical e respectiva concordância radiográficapt_BR
dc.title.alternativeClinical study of the accuracy of electronic location in constriction apical and their respective radiographic agreementen
dc.typeDissertaçãopt_BR

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
vanessa_cruz_silva_fernandes.pdf
Size:
1.12 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.06 KB
Format:
Item-specific license agreed upon to submission
Description: