Otimização e validação de metodologias de extração para determinação do fluopiram em amostras de água e solo

dc.contributor.advisorSilvério, Flaviano Oliveira
dc.contributor.advisorcoSicupira, Lázaro Chaves
dc.contributor.authorTerra, Gleysson de Paula
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.contributor.refereeSilvério, Flaviano Oliveira
dc.contributor.refereeFerreira, Giovana Ribeiro
dc.contributor.refereePinho, Gevany Paulino de
dc.contributor.refereeCastricini, Ariane
dc.contributor.refereeFidêncio, Paulo Henrique
dc.date.accessioned2023-04-11T22:20:17Z
dc.date.available2023-04-11T22:20:17Z
dc.date.issued2023
dc.date.submitted2023-02-10
dc.description.abstractO fluopiram é um fungicida desenvolvido pela Bayer Crop Science e atua contra fungos fitopatogênicos inibindo a enzima succinato desidrogenase. Essa molécula também possui ação nematicida. Recentemente surgiram preocupações a respeito dos efeitos toxicológicos devido ao uso extensivo deste composto na agricultura. Diante deste cenário, o monitoramento contínuo deste analito no ambiente e em matrizes alimentares é importante e necessário para assegurar a saúde das pessoas e do meio ambiente. Para este monitoramento, tem sido necessário o desenvolvimento de novas metodologias de extração que sejam fáceis de executar, de baixo custo e suficientemente sensíveis, exatas e precisa. Por isso, este trabalho teve como objetivo otimizar e validar a extração líquido-líquido com purificação em baixa temperatura (ELL-PBT) para determinar o fluopiram em amostras de água por cromatografia líquida de alta eficiência com detecção por arranjo de diodos (CLAE-DAD) e extração sólido-líquido com purificação em baixa temperatura (ESL-PBT) na versão miniaturizada para determinação deste composto em amostras de solos arenosos, argilosos e com textura média e detecção por cromatografia em fase gasosa acoplada à espectrometria de massas (CG-EM). Estes dois métodos de extração ainda não foram aplicados com esta finalidade neste composto. É importante destacar que uma das principais vantagens destes métodos de extração tem sido a ausência de uma etapa de limpeza, o que torna o método mais rápido e fácil de executar. Além disso, estes métodos são mais econômicos que os demais. Foi empregado o planejamento fatorial completo com dois níveis e três fatores para otimizar a ELL-PBT que permitiu alcançar uma taxa de recuperação próxima de 100% e desvios padrão relativos inferiores a 10%. A validação mostrou que o método de extração pode ser considerado seletivo, preciso, exato e linear na faixa de 6 a 200 μg L-1. Os limites de detecção e de quantificação foram de 4 e 6 μg L-1, respectivamente, comprovando a eficiência deste método para determinação deste fungicida em amostras de água. A ELL-PBT combinada à análise por CLAE-DAD mostrou um efeito de matriz inferior a 8% e foi aplicado no monitoramento de 20 amostras ambientais de água, mas nenhum resíduo do fluopiram foi detectado nas amostras. Na versão miniaturizada do método ESL-PBT, todas as análises foram realizadas por cromatografia em fase gasosa acoplada à espectrometria de massas no modo seletivo de íons. Os resultados revelaram que as porcentagens de recuperação do analito nos três tipos de solos variaram de 86 a 114% com desvio padrão relativo inferior a 15%. Além de empregar menores quantidades de reagentes e amostra, o método ESL-PBT miniaturizado se apresentou seletivo, preciso, exato, linear na faixa de 3 a 210 μg kg-1 e atingindo um limite de quantificação inferior a 3 μg kg-1 para os três tipos de solos. O método de extração otimizado e validado foi aplicado em 30 amostras reais coletadas em regiões de cultivo de café, porém não foi detectada nestas amostras nenhum resíduo deste composto. Este trabalho assim como outras publicações demonstram a versatilidade e eficiência da aplicação do método de ELL-PBT e ESL-PBT dando respaldo para a sua utilização na determinação de diversos contaminantes.pt_BR
dc.description.abstractsFluopyram is a fungicide developed by Bayer Crop Science and acts against phytopathogenic fungi by inhibiting the enzyme succinate dehydrogenase. This molecule also has nematicidal action. Recently, concerns have arisen regarding the toxicological effects that may occur due to its extensive use of this compound in agriculture. Given this scenario, continuous monitoring of this analyte in the environment and in food matrices is important and necessary to ensure the health of people and the environment. For this monitoring, it has been necessary to develop new extraction methodologies that are easy to perform, low cost and sufficiently sensitive, accurate and precise. Therefore, this work aimed to optimize and validate the liquid-liquid extraction with low temperature purification (LLE-LTP) to determine fluopyram in water samples by high performance liquid chromatography with diode array detection (HPLC-DAD) and miniaturized solid-liquid extraction with low temperature purification (SLE-LTP) to determine this compound in samples of sandy, clayey and medium textured soils and detection by gas chromatography coupled to mass spectrometry (GC-MS). These two methods have not yet been applied for this purpose on this compound. It is important to highlight that one of the main advantages of these ELL-PBT and ESL-PBT extraction methods is the absence of a cleaning, which makes the method faster and easier to perform. In addition, these methods are more economical than others. A full factorial design with two levels was used to optimize the LLE-LTP, which allowed achieving a recovery rate close to 100% and relative standard deviations below 10%. The validation showed that the extraction method can be considered selective, precise, accurate and linear in the range of 6 to 200 μg L-1. The limits of detection and quantification were 4 and 6 μg L-1, respectively, proving the efficiency of this method for determining this fungicide in water samples. LLE-LTP combined with HPLC-DAD analysis showed a matrix effect of less than 8% and was applied to monitor 20 environmental water samples, but no fluopyram residues were detected in the samples. All analyzes in the miniaturized SLE-LTP method were performed by gas chromatography coupled to ion-selective mass spectrometry. The results revealed that the analyte recovery percentages in the three soil types ranged from 86 to 114% with a relative standard deviation of less than 15%. In addition to using smaller amounts of reagents and sample, the miniaturized SLE-LTP method was selective, precise, accurate, and linear in the range of 3 to 210 μg kg-1 and reached a quantification limit of less than 3 μg kg-1 for the three soil types. The optimized and validated extraction method was applied to 30 real samples collected in coffee growing regions, but no residue of this compound was detected in these samples. This work, as well as other publications, demonstrate the versatility and efficiency of applying the LLE-LTP and SLE-LTP methods, supporting their use in determining various contaminants.en
dc.description.thesisTese (Doutorado) – Programa de Pós-Graduação Multicêntrico em Química de Minas Gerais, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2023.pt_BR
dc.identifier.citationTERRA, Gleysson de Paula. Otimização e validação de metodologias de extração para determinação do fluopiram em amostras de água e solo. 2023. 109 p. Tese (Doutorado Multicêntrico em Química) – Programa de Pós-Graduação Multicêntrico em Química de Minas Gerais, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2023.pt_BR
dc.identifier.urihttps://acervo.ufvjm.edu.br/items/40b2c820-8297-4e3f-8890-57d226a809c2
dc.language.isopor
dc.publisherUFVJMpt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.subject.keywordFluopirampt_BR
dc.subject.keywordFungicidapt_BR
dc.subject.keywordELL-PBTpt_BR
dc.subject.keywordESL-PBT miniaturizadapt_BR
dc.subject.keywordFluopyramen
dc.subject.keywordFungicideen
dc.subject.keywordLLE-LTPen
dc.subject.keywordMiniaturized SLE-LTPen
dc.titleOtimização e validação de metodologias de extração para determinação do fluopiram em amostras de água e solopt_BR
dc.typeTesept_BR

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
gleysson_paula_terra.pdf
Size:
1.06 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.11 KB
Format:
Item-specific license agreed upon to submission
Description: