Desenvolvimento e validação de um sensor para a determinação de L-DOPA em medicamentos empregando um eletrodo a base de nanotubos de carbono modificados com Co(DMG)2ClPy

dc.contributor.advisorLuz, Rita de Cássia Silva
dc.contributor.authorLeite, Fernando Roberto Figueirêdo
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.contributor.refereeLuz, Rita de Cássia Silva
dc.contributor.refereeDamos, Flávio Santos
dc.contributor.refereePereira, Arnaldo César
dc.date.accessioned2015-02-20T10:58:09Z
dc.date.available2015-02-20T10:58:09Z
dc.date.issued2011
dc.date.submitted2011-03-22
dc.description.abstractL-Dopa é convertida em dopamina no cérebro e continua a ser a droga mais amplamente prescrita no tratamento da doença de Parkinson. Um sensível e seletivo sensor foi desenvolvido para a determinação voltamétrica de L-Dopa em formulações farmacêuticas usando um Eletrodo de Grafite Pirolítico de Plano Basal (EGPPB) modificado com cloro(piridil)bis(dimetilglioximato) de cobalto (III) (Co(DMG)2ClPy), um modelo sintético da vitamina B12, adsorvido em Nanotubos de Carbono de Paredes Múltiplas (NCPM), o qual foi denominado EGPPB/NCPM/Co(DMG)2ClPy. Microscopia Eletrônica de Varredura e Espectroscopia no Infravermelho por Transformada de Fourier foram utilizadas para caracterizar os materiais. A oxidação de L-Dopa utilizando o EGPPB/NCPM/Co(DMG)2ClPy foi investigada por Voltametria Cíclica, Amperometria, Voltametria de Pulso Diferencial e Voltametria de Onda Quadrada. O eletrodo modificado apresentou uma excelente atividade catalítica para a oxidação de L-Dopa em 180 mV vs. Ag/AgCl. Os parâmetros que influenciam a resposta do eletrodo foram investigados. As condições ótimas foram encontradas para o eletrodo modificado com 100 μmol L-1 de Co(DMG)2ClPy, 2 mg mL-1 de NCPM, em solução tampão fosfato na concentração de 0,2 mol L-1 (pH 7,4). O número de elétrons envolvidos na oxidação de L-Dopa foi igual a dois. As correntes de pico voltamétricas apresentaram uma resposta linear para a concentração de L-Dopa no intervalo de 3 a 100 μmol L-1 para n = 12 (R = 0,9992), com sensibilidade, limite de detecção e limite de quantificação iguais a 4,43 μA cm-2/μmol L-1, 0,86 e 2,87 μmol L-1, respectivamente. O Desvio Padrão Relativo para 10 determinações de solução 50 μmol L-1 de L-Dopa foi de 1,63%. Os resultados obtidos para a determinação de L-Dopa em formulações farmacêuticas estão de acordo com o método de comparação oficial. Estudos de adição e recuperação do analito foram realizados para avaliar a exatidão do método e verificou-se que foi possível uma porcentagem de recuperação entre 99,4 e 101,5% para a L-Dopa. Portanto, o sensor desenvolvido pode ser aplicado com sucesso para a determinação do referido fármaco em medicamentos.pt_BR
dc.description.abstractsABSTRACT L-Dopa is converted to dopamine in the brain and remains the most widely prescribed drug in the treatment of Parkinson's disease. A sensitive and selective method was developed for the voltammetric determination of L-Dopa in pharmaceutical formulations using a Basal Plane Pyrolytic Graphite Electrode (BPPGE) modified with chloro(pyridil)bis(dimethylglyoximato)cobalt(III) (Co(DMG)2ClPy), synthetic model of vitamin B12, absorbed on Multi-walled Carbon Nanotube (MWCNT), denominated MWCNT/Co(DMG)2ClPy/BPPGE. Scanning Electron Microscopy and Fourier Transform Infrared Spectroscopy were used to characterize the materials. The oxidation of L-Dopa using the MWCNT/Co(DMG)2ClPy/BPPGE was investigated by Cyclic Voltammetry, Amperometry, Differential Pulse Voltammetry and Square Wave Voltammetry. The modified electrode showed an excellent catalytic activity for L-Dopa oxidation at 180 mV vs. Ag/AgCl. The parameters that influence on the electrode response were investigated. The optimum conditions were found to the modified electrode with 100 μmol L-1 Co(DMG)2ClPy, 2 mg mL-1 MWCNT, in 0.2 mol L-1 phosphate buffer solution (pH 7.4). The number of electrons involved in L-Dopa oxidation was two. Voltammetric peak currents showed a linear response for L-Dopa concentration in the range from 3 up to 100 μmol L-1 for n = 12 (R = 0.9992), with a sensitivity, detection limit and quantification limit of 4.43 μA cm-2/μmol L-1, 0.86 and 2.87 μmol L-1, respectively. The Relative Standard Deviation for 10 determinations of 50 μmol L-1 L-Dopa was 1.63%. The results obtained for L-Dopa determination in pharmaceutical formulations was in accordance with the official method of comparison. Studies of addition and recovery of the analyte were carried out to evaluate the error of the method and was verified a recovery percentage between 99.4 and 101.5% for L-Dopa. Therefore the sensor developed can be applied successfully to the determination of this drug in pharmaceuticals formulations.en
dc.description.thesisDissertação (Mestrado) – Programa de Pós-Graduação em Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2011.pt_BR
dc.identifier.citationLEITE, Fernando Roberto Figueirêdo. Desenvolvimento e validação de um sensor para a determinação de L-DOPA em medicamentos empregando um eletrodo a base de nanotubos de carbono modificados com Co(DMG)2ClPy2. 2011. 84 p. Dissertação (Mestrado) – Programa de Pós-Graduação em Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2011.pt_BR
dc.identifier.urihttp://acervo.ufvjm.edu.br:8080/jspui/handle/1/517
dc.language.isopor
dc.publisherUFVJMpt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.subject.keywordQuímicapt_BR
dc.subject.keywordCiências Exataspt_BR
dc.subject.keywordQuímica analíticapt_BR
dc.subject.keywordOxidação de L-Dopapt_BR
dc.subject.keywordSensorpt_BR
dc.subject.keywordCloro(piridil)bis(dimetilglioximato) de cobalto (III)pt_BR
dc.subject.keywordNanotubos de Carbono de Paredes Múltiplaspt_BR
dc.subject.keywordGrafite Pirolítico de Plano Basalpt_BR
dc.titleDesenvolvimento e validação de um sensor para a determinação de L-DOPA em medicamentos empregando um eletrodo a base de nanotubos de carbono modificados com Co(DMG)2ClPypt_BR
dc.title.alternativeDevelopment and validation of a sensor for the determination of L-Dopa in pharmaceuticals formulations using an electrode based on carbon nanotubes modified with Co(DMG)2ClPyen
dc.typeDissertaçãopt_BR

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
fernando_roberto_figueiredo_leite.pdf
Size:
3.37 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.06 KB
Format:
Plain Text
Description: