Viabilidade de um sistema geotérmico de climatização aplicado a um supermercado do sudeste brasileiro
dc.contributor.advisor | Alexandrino, Carlos Henrique | |
dc.contributor.author | Gonçalves, Hugo Henrique Azevedo | |
dc.contributor.institution | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.date.accessioned | 2022-12-13T19:27:15Z | |
dc.date.available | 2022-12-13T19:27:15Z | |
dc.date.issued | 2022 | |
dc.date.submitted | 2022-09-06 | |
dc.description.abstract | A climatização de ambientes consome nos dias atuais significativa parcela de energia nos edifícios brasileiros. Com o aquecimento global e o constante desenvolvimento social e tecnológico, a expectativa é de aumento deste consumo em um futuro próximo, o que eleva o interesse em sistemas de climatização com alta eficiência energética, como os Sistemas Geotérmicos de Climatização (SGC) (Ground Source Heat Pump systems (GSHPs). Estes, são sistemas sustentáveis que utilizam o solo como fonte/dissipador de energia, alcançando melhores eficiências que os tradicionais sistemas a ar devido à estabilidade térmica do solo já em baixas profundidades. O presente estudo teve por objetivo avaliar a viabilidade de utilização de um SGC aplicado a um supermercado da cidade de Diamantina/MG. Para isso, foi feito um estudo de caso em que, para as condições reais de um supermercado, se comparou o comportamento de um SGC ao comportamento de um sistema de ar-condicionado (A/C). Inicialmente, se fez uma simulação termo energética do supermercado a fim de se obter suas cargas térmicas e se estimar os consumos de energia dos sistemas de A/C de referência. Na sequência, foram feitas análises de viabilidade técnica concomitantes aos dimensionamentos de dez configurações de SGC: três verticais e sete horizontais. Propôs-se, então, uma configuração ótima que passou por análise de viabilidade econômica. Como resultados, pôde-se observar que o clima da região leva o supermercado a possuir demandas de climatização para conforto térmico, mas não permite uma integração de aplicações como sugerem os trabalhos correlatos. O SGC proposto foi um sistema vertical composto por 36 poços de 62,1 metros de profundidade, se mostrando a mais adequado tecnicamente por apresentar melhor eficiência energética e requerer menores comprimentos de tubulações. Essa configuração apresentou uma redução anual média de 20,1% no consumo de energia elétrica em relação ao sistema de A/C, confirmando-se ser viável tecnicamente. A avaliação econômica, porém, mostrou que o SGC proposto é inviável para as condições atuais de mercado, sendo os custos de aquisição das bombas de calor e das perfurações dos poços no solo os principais contribuintes para este resultado. | pt_BR |
dc.description.abstracts | The air conditioning of environments currently consumes a significant portion of energy in Brazilian buildings. With global warming and the constant social and technological development, this consumption is expected to increase in the near future, which raises the interest in air conditioning systems with high energy efficiency, such as Geothermal Ground Source Heat Pump systems (GSHPs). These are sustainable systems that use the soil as an energy source/dissipator, achieving better efficiencies than traditional air systems due to the thermal stability of the soil at low depths. The present study aimed to assess the feasibility of using a GSHP applied to a supermarket in the city of Diamantina / MG. For this, a case study was made in which, for the real conditions of a supermarket, it was compared the behavior of a GSHP to the behavior of an air-conditioning system (A/C). Initially, a thermal-energy simulation of the supermarket was done in order to obtain its thermal loads and to estimate the energy consumption of the reference A/C systems. Next, technical feasibility analyses were carried out concomitant to the sizing of ten GSHPs configurations: three verticals and seven horizontals. Then, an optimum configuration was proposed and analyzed for economic feasibility. As results, it could be observed that the region's climate leads the supermarket to have acclimatization demands for thermal comfort, but it does not allow an integration of applications as suggested by correlated works. The proposed GSHP was a vertical system composed by 36 boreholes with 62.1 meters deep, was the most suitable technically, because it presents a better energy efficiency and requires smaller piping lengths. This configuration showed an average annual reduction of 20.1% in electricity consumption compared to the A/C system, confirming its technical feasibility. The economic evaluation, however, showed that the proposed SGC is unfeasible for the current market conditions, with the costs of acquiring heat pumps and drilling wells in the ground being the main contributors to this result. | pt_BR |
dc.description.sponsorship | Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM) | pt_BR |
dc.description.thesis | Dissertação (Mestrado Profissional) – Programa de Pós-Graduação em Tecnologia, Ambiente e Sociedade, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2022. | pt_BR |
dc.identifier.citation | GONÇALVES, Hugo Henrique Azevedo. Viabilidade de um sistema geotérmico de climatização aplicado a um supermercado do sudeste brasileiro. 2022. 142 p. Dissertação (Mestrado Profissional em Tecnologia, Ambiente e Sociedade) – Programa de Pós-Graduação em Tecnologia, Ambiente e Sociedade, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Teófilo Otoni, 2022. | pt_BR |
dc.identifier.uri | https://acervo.ufvjm.edu.br/items/1777d8f9-98e3-43fb-927a-44777cb96b42 | |
dc.language.iso | por | |
dc.publisher | UFVJM | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.license | A concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data. | pt_BR |
dc.subject.keyword | Geotermia superficial | pt_BR |
dc.subject.keyword | Sistema geotérmico de climatização | pt_BR |
dc.subject.keyword | Ground source heat pump | pt_BR |
dc.subject.keyword | Eficiência energética | pt_BR |
dc.subject.keyword | Climatização de ambientes | pt_BR |
dc.title | Viabilidade de um sistema geotérmico de climatização aplicado a um supermercado do sudeste brasileiro | pt_BR |
dc.type | Dissertação | pt_BR |