Caracterização e avaliação da resistência à adesão de sistema adesivo dentário processado com nanopartículas de hidroxiapatita

dc.contributor.advisorSantos, Maria Helena
dc.contributor.advisorcoBotelho, Adriana Maria
dc.contributor.authorDumont, Vitor César
dc.contributor.institutionUniversidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)pt_BR
dc.contributor.refereeSantos, Maria Helena
dc.contributor.refereeTavano, Karine Taís Aguiar
dc.contributor.refereePereira, Marivalda de Magalhães
dc.date.accessioned2015-12-01T17:04:58Z
dc.date.available2015-12-01T17:04:58Z
dc.date.issued2013
dc.date.submitted2013-02-01
dc.description.abstractO presente estudo modificou um sistema adesivo polimérico convencional (AC) com nanopartículas de hidroxiapatita (HAP) como carga, caracterizou os compósitos desenvolvidos e avaliou sua efetividade adesiva à estrutura dentária. Depois de bem limpos e esterilizados em autoclave, pré-molares recém-extraídos por indicação ortodôntica em grupos etários inferior a 21 anos, foram seccionados no sentido horizontal, obtendo-se o terço médio da coroa do dente. Este foi seccionado novamente, no seu sentido vertical, obtendo-se duas secções, que foram incluídas em tubo de policloreto de vinila (2 cm de diâmetro x 1,5 cm de altura) preenchidos com resina poliéster. Em metade dos espécimes foram expostas superfícies em esmalte e na outra metade superfícies em dentina. Na primeira etapa, as secções foram divididas em oito grupos (n = 6), em esmalte (E): G1 – AC; G2, G3 e G4 - AC modificado com 0,05, 0,10 e 0,15 g/ml de HAP, respectivamente; e em dentina (D): G5 – AC; G6, G7 e G8 - AC com as mesmas concentrações de HAP utilizadas em esmalte. Decorridos 14 dias em água destilada a 37 ºC (± 1°C), as amostras foram submetidas ao teste de microcisalhamento em uma máquina universal de ensaio. As áreas de fratura dos espécimes foram analisadas por microscopia de Luz (ML) e amostras representativas de cada grupo foram caracterizadas por microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva de raios-X (EDS). Apesar da média dos valores de resistência à adesão dos grupos AC modificados com HAP se apresentar mais alta, principalmente em esmalte, não houve significância estatística entre os grupos (ANOVA), (p>0,05). Maior quantidade de falhas adesivas foi observada na interface de união. Na segunda etapa, as coroas dos dentes foram seccionadas como anteriormente e as secções foram divididas em 10 grupos (n = 15): G1E e G1D – AC; G2E e G2D - AC-adesivo modificado com 0,10 g/ml de HAP; G3E e G3D - AC-primer modificado com 0,10 g/ml de HAP; G4E e G4D - sistema adesivo monocomponente; G5E e G5D - sistema adesivo autocondicionante. Após 14 dias, os espécimes foram submetidos ao teste de microcisalhamento. As áreas de fratura dos grupos foram analisadas por ML e amostras representativas foram caracterizadas por MEV/EDS. Os compósitos modificados e seus materiais precursores foram caracterizados através de difração de raios-X (XRD) e espectroscopia de infravermelho por transformada de Fourier (FTIR). Diferença estatisticamente significativa foi observada entre os grupos (Kruskal-Wallis), (p<0,01), em E e D. G3 apresentou os maiores valores de resistência à adesão em esmalte (64,40MPa, ±7,36) e em dentina (39,59 MPa, ±21,46). A análise das interfaces sistema adesivo/estrutura dentária mostrou a presença de fraturas adesivas na maioria dos espécimes. Fraturas coesivas foram encontradas em G2E, G3E, G4E e G3D. Verificou-se que os compósitos desenvolvidos com a incorporação de nanopartículas de HAP à sua composição (G3E e G3D) mostraram melhoria significativa na resistência de adesão à estrutura dentária. Os compósitos apresentaram-se estáveis, com fases cristalográficas e amorfas, e mostraram morfologia e estrutura química similares aos seus materiais precursores.pt_BR
dc.description.abstractsABSTRACT The present study modified a conventional polymer adhesive system (AC) with nanoparticles of hydroxyapatite (HAP) as filler, characterized the composites developed and evaluated its adhesive effectiveness to tooth structure. After completely cleaned and sterilized in an autoclave, premolars recently extracted under orthodontic indication in groups aged below 21 years, were sectioned horizontally, providing the middle third of the crown of the tooth. This one was sectioned again vertically, resulting in two sections which were embedded in polyvinyl chloride tube (2 cm diameter x 1.5 cm high) filled with polyester resin. In half of the specimens, enamel surfaces were exposed and in the other half, dentine surfaces. In the first stage, the sections were divided into eight groups (n = 6) in enamel (E): G1 – AC; G2, G3 and G4 - AC modified with 0.05, 0.10 and 0.15 g / ml HAP, respectively; and in dentin (D): G5 – AC; G6, G7 and G8 - AC with the same concentrations of HAP used in enamel. After 14 days in distilled water at 37 ° C (± 1 ° C), the specimens were submitted to a micro-shear test on a universal testing machine. The specimens’ fractures were observed under light microscopy (LM) and representative samples of each group were characterized by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Although the average values of the bond strength of the groups AC modified with HAP presented to be higher, mainly in enamel, there was no statistical significance between the groups (ANOVA), (p > 0.05). Larger amount of adhesive failures were observed at the interface bond. In the second stage, the teeth were sectioned as previously and the sections were divided into 10 groups (n = 15): G1E and G1D – AC; G2E and G2D – AC – adhesive modified with 0.10 g / ml HAp, G3E and G3D – AC – primer modified with 0.10 g / ml of HAp; G4E and G4D – single-component adhesive system; G5E and G5D – auto-conditioning adhesive system. After 14 days, the specimens were submitted to micro-shear testing. The areas of fracture in the groups were analyzed by LM and representative samples were characterized by SEM / EDS. The modified composites and their precursor materials were characterized by X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). A statistically significant difference was observed between groups (Kruskal-Wallis), (p <0.01) in E and D. G3 presented the highest values of resistance to adhesion in enamel (64.40 MPa ± 7.36) and in dentin (39.59 MPa ± 21.46). The analysis of the interfaces adhesive system / tooth structure showed the presence of adhesive fractures in most specimens. Cohesive fractures were found in G2E, G3E, G4E and G3D. It was found that the composites developed with incorporation of nanoparticles of HAP to their composition (G3E and G3D) showed significant improvement in the bond strength to tooth structure. The composites were stable, with crystalline and amorphous phases, and showed morphology and chemical structure similar to their precursor materials.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do estado de Minas Gerais (FAPEMIG)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.thesisDissertação (Mestrado) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2013.pt_BR
dc.identifier.citationDUMONT, Vitor César. Caracterização e avaliação da resistência à adesão de sistema adesivo dentário processado com nanopartículas de hidroxiapatita. 2013. 74 p. Dissertação (Mestrado) – Programa de Pós-Graduação em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, 2013.pt_BR
dc.identifier.urihttp://acervo.ufvjm.edu.br:8080/jspui/handle/1/763
dc.language.isopor
dc.publisherUFVJMpt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.licenseA concessão da licença deste item refere-se ao à termo de autorização impresso assinado pelo autor, assim como na licença Creative Commons, com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus repositórios, sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, e preservação, a partir desta data.pt_BR
dc.subject.keywordAdesivos dentáriospt_BR
dc.subject.keywordPolímerospt_BR
dc.subject.keywordBiomateriaispt_BR
dc.subject.keywordHidroxiapatitapt_BR
dc.subject.keywordMicroscopiapt_BR
dc.subject.keywordResistência à adesãopt_BR
dc.titleCaracterização e avaliação da resistência à adesão de sistema adesivo dentário processado com nanopartículas de hidroxiapatitapt_BR
dc.title.alternativeCharacterization and evaluation of the bond strength of dental adhesive system processed with nanoparticles of hydroxyapatiteen
dc.typeDissertaçãopt_BR

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
vitor_cesar_dumont.pdf
Size:
1.79 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2 KB
Format:
Item-specific license agreed upon to submission
Description: